Subscribe to our weekly newsletters
Subscribe to newsletter

 

Editor's Note:  Tyco Thermal Controls provide:-

electrical cable cable core wiring cable fire systemselectrical cable
electrical cable cable core wiring cable fire systemscable core
electrical cable cable core wiring cable fire systemswiring cable
electrical cable cable core wiring cable fire systemsfire systems

Request Information

Home
Include Article
Advertise
 

Links
Request Information
Terms of use
Contact

 

Request Facilities / Interiors product information

Request Architectural product information External

Request Architectural product information Internal

Request Mechanical HVAC product information

Request Electrical product information

 

 

 

   

Pyro Mi cables successfully witness tested to the stringent fire test methodology of BS7346-6:2005

Tyco Thermal Controls has led the way by example in having its Pyro MI mineral-insulated cables undergo Lloyds Register witness testing under the new, more stringent, fire test methodology of BS 7346-6:2005. This cable successfully achieved the highest performance requirement of 120 minutes survival time for fire fighting systems. The Standard applies to cables above a notional size of 20mmØ, but also recognises smaller cables that can be accommodated in the test rig. As many MI cable sizes typically used for life safety and fire fighting circuits are significantly smaller and lighter than other cables of an equivalent rating in the Standard, Tyco Thermal Controls also took the opportunity to subject Pyro MI cables down to12mmØ to the same rigorous tests and were able to demonstrate that these too will meet the highest fire performance requirements.

BS 7346-6:2005 is the recently introduced Standard for fire-rated cable systems, defining the performance requirements of various types of fire-rated cables (up to 600/1000V) in maintaining circuit integrity for life safety, fire-fighting and property protection systems under fire conditions.
With the introduction of BS7346 in respect of fire-rated components, and specifically in Part 6 - Specification for cable systems, the British Standards Institute addressed the long standing concerns with respect to fire test methodology.
These had been earlier recognised in the commentary to BS 5839-1:2002, for fire alarm cables that identified a need for revision of the test methods of BS 6387 (for which the test rig is limited to smaller cables up to approx 20mmØ) to more accurately replicate the physics of a real fire scenario.

BS 7346-6:2005 introduces new test methods to assess cable performance under conditions of direct application of fire, direct mechanical impact and fire-fighting water shock – all conditions associated with a real fire incident. Where previously each element of a test was conducted on a separate cable sample, this Standard requires the complete test to be applied to a single cable sample and, for the first time, it is subjected to direct mechanical shock and water jet impacts.

The test methodology has been devised, for a single cable sample, to validate that the fire-rated cable will maintain circuit integrity for the required survival time whilst simultaneously:
• withstanding a constant temperature attack at 842°C
• withstanding repeated direct impact shock of approx 10N at 10 minute intervals.
• withstanding direct water jet impact equivalent to a 2 bar water hose at the point of mechanical impact during the last 5 minutes of the required survival time.

The BS 7346-6 Standard describes two classes of system, Life Safety and Fire Fighting which, when applied, determine the appropriate performance requirement according to the function of each circuit.
Life Safety requires control systems to remain functional for alarm and to support evacuation. Suggested survival time requirements assessed as being for instance 30 minutes for single stage evacuation or 60 minutes for multi-stage evacuation.
Fire fighting systems require circuit integrity for 120 minutes to serve active systems for protecting and assisting fire-fighters in carrying out their role and would typically include pressure differential systems for fire-fighting, smoke and heat exhaust ventilation, sprinklers and fire fighting lifts.

Contained in the Standard are a table and an annex which provide a matrix of suggested survival times to meet different fire performance objectives. Obviously, if for practical reasons a single cable type is to be employed for all applications then it would need to have the maximum fire survival performance to maintain full system integrity.

Most active fire safety systems in buildings rely on a dependable electrical power supply for detection, alarms, evacuation and communication thereby enabling safe evacuation and assisting the fire fighting response. In the event of fire it is critical for electrical circuit integrity, for power, signal & control, to sustain operation systems incorporating equipment such as, sprinkler pumps, shutters and smoke curtains, smoke ventilation systems, fire fighting lifts, smoke control dampers and pressurisation fans. The electric cables which maintain power, control and signals to such equipment are fundamental to the task.

By introducing a more accurate replication of fire dynamics into cable test methodology and classifying objectives, BS 7346-6 offers fire safety engineers a meaningful guide to the capability of different fire performance cables in respect of their application.
Within the new Standard, building services engineers and fire engineers, responsible for specifying fire-rated cable systems into ever more complex buildings, are provided with clear guidance for the selection of appropriate fire-rated cables to support Life Safety and Fire Fighting applications.

Email: SalesUK@tycothermal.com


Polyflor Ltd safety flooring commercial flooring vinyl floor tiles floor covering news 260706

Polyflor Ltd sheet vinyl flooring playground surface safety surface vinyl sheet news 120706

Polyflor Ltd sports surfaces safety flooring sheet vinyl flooring vinyl floor covering news 300506

Polyflor safety flooring sports surfaces flooring tile commercial flooring news 200406

17-Polyflor safety flooring sports surfaces non slip flooring News 010508

Polyflor safety flooring sports surfaces non slip flooring floor coverings news 070406

Polyflor sports surfaces floor safety commercial flooring vinyl floors news 290606

Polyflor Sports Surfaces Safety Flooring news 210606

Poujoulat (UK) Ltd chimney construction steel chimney chimney uk news 280706

Poundfield Products brick ties wall system block system masonry reinforcement news 190106

Poundfield Products concrete retaining wall retaining blocks brick ties wall system news 190106

Poundfield Products Ltd retaining wall blocks wall systems brick ties news 020606

Poundfield Products retaining blocks brick ties wall system block system news 190106

Poundfield Products wall ties cavity wall ties masonry support systems news 130306

Poundfield Products wall ties cavity wall ties wall block masonry brick news 270606

Poundfield Products wall ties masonry wall concrete retaining wall retaining blocks news 190106

PRI Limited energy metering electricity metering power management system news 120706

PRI Limited energy metering energy management software energy management systems news 120706

Propencity Group building service construction services building work building development news 140906

Pure Window Water Company pure water systems reverse osmosis system window cleaning system News 100107

Quinn Plastics Ltd roof glazing plastic sheeting plastic roof sheets plastic roofing news 280406

Quinn Plastics plastic roofing plastic roof sheets lightweight roofing roofing material news 160106

Quinn Plastics polycarbonate roofing commercial roofing sheet roofing polycarbonate roofing sheets news 170206

Rainbow Professional tree surgery landscaping trees tree protection tree services news 100106

Ransfords facing bricks mortar bricks brick suppliers wall bricks news 210606

Real Door Company hardwood doors internal doors uk bespoke doors news 040506

 

Arundel Jones Associates Ltd Registered in England and Wales No. 07334149
Hill Farm, Linton Hill, Maidstone, Kent ME 17 4AL
Tel : 01622 745333 email
copyright all rights reserved

News Categories : Tyco Thermal Controls electrical cable cable core wiring cable fire systems